Introduction
Internal jugular vein (IJV) cannulation is a routine procedure in operating rooms, critical care units, and perioperative settings. Ultrasound guidance has notably increased the success rates of IJV cannulation. A modified ultrasound technique known as the short-axis out-of-plane method with dynamic needle tip positioning (DNTP) allows for continuous visualization of the needle tip throughout the procedure. This study aims to compare the first-pass success rate of IJV cannulation using the DNTP and long-axis in-plane (LAIP) approaches.
Methods
One hundred patients between 18 and 70 years undergoing elective surgery requiring IJV cannulation were recruited. Patients were assigned randomly to the DNTP group (n = 50) or the LAIP group (n = 50). We recorded the first-pass success rate, time to achieve successful cannulation, number of skin punctures, overall success rate within five minutes, and potential complications such as pneumothorax and hematoma.
Results
The first pass success rate was higher in the DNTP group (48/50, 96%) as compared to the LAIP group (38/50, 76%, relative risk, 1.67; 95% confidence interval, 0.039-0.707; p = 0.008). The cannulation time was shorter in DNTP (116.98 ± 22.90 seconds) versus the LAIP group (213.04 ± 52.08 seconds; p < 0.001). No complications like pneumothorax or hematoma were noted in both groups.
Conclusion
We conclude that the ultrasound-guided DNTP technique for IJV cannulation, as compared with the LAIP technique, may significantly improve the first attempt cannulation, number of attempts, and cannulation time.
Leave a Reply