Extracorporeal membrane oxygenation (ECMO) is associated with a high risk of bleeding complications. The specific impact of ECMO on fibrinolysis remains unexplored. The objective of the current pilot observational prospective study was to investigate the longitudinal dynamics of fibrinolytic markers—i.e., changes over time—in the context of bleeding events in patients on ECMO.
Longitudinal dynamics of contact phase components (kininogen and bradykinin) and fibrinolysis markers (tissue plasminogen activator [tPA], plasminogen activator inhibitor-1 [PAI-1], their complexes [tPA•PAI-1], plasmin–antiplasmin complexes, plasminogen, and D-dimer) were measured in patients undergoing venovenous and venoarterial ECMO, before implantation, at 0, 6, and 12 h after implantation, and daily thereafter.
The cohort consisted of 30 patients (214 ECMO days). The concentrations of tPA, D-dimer, plasmin–antiplasmin complexes, PAI-1, and tPA•PAI-1 complexes were increased, whereas plasminogen decreased compared to normal values. A noteworthy divergence was observed between hemorrhagic and nonhemorrhagic patients: in bleeding patients, D-dimer, plasmin–antiplasmin, tPA, PAI-1, and tPA•PAI-1 followed an increasing kinetics before hemorrhage and then decreased to their baseline level; conversely, nonbleeding patients showed a decreasing kinetics in these markers. Also, D-dimer and tPA followed an increasing kinetics in bleeding patients compared to nonbleeding patients (median values for D-dimer dynamics: 1,080 vs. –440 ng/ml, P = 0.05; tPA dynamics: 0.130 vs. 0.100 nM, P = 0.038), and both markers significantly increased the day before hemorrhage. A tPA concentration above 0.304 nM was associated with bleeding events (odds ratio, 4.92; 95% CI, 1.01 to 24.08; P = 0.049).
Contact activation induces fibrinolysis in ECMO patients, especially in patients experiencing bleeding. This finding supports the role of this mechanism as a possible causal factor for hemorrhages during ECMO and open new avenues for novel therapeutic perspectives.
- Extracorporeal membrane oxygenation (ECMO) is associated with a high risk of bleeding complications due to multiple factors. However, the role of the fibrinolytic system is not well understood in this setting.
- In patients requiring cardiac and/or pulmonary support with ECMO, D-dimer and tissue plasminogen activator levels were increased with bleeding, findings consistent with fibrinolysis.
- Although there are multiple causes for fibrinolysis during ECMO, their study suggests that patients who bled had increased contact activation and may benefit from novel therapeutic agents that inhibit hemostatic activation through this pathway.